Electrode integrated sensor that together with the environment forms a capacitor. Depending on its dielectric constant (DC value), the medium determines the capacity value. This, together with a coil in the sensor electronics, creates a resonance circuit. Depending on the measured resonance frequency and the programmable trigger thresholds, the switching signal is triggered.
610 Ref. L1, L2, L3
620 Ref. L1, L2, L3, L4, L5, L6, L7, L11, L12
621 Ref. L1, L2, L3, L4, L5, L6, L7, L11, L12
830 Ref. L1, L2, L3, L4, L5, L6, L7, L11, L12
810 Ref L2
812 Ref L2
liquid level
-40...85°C
PNP
connector M12
programmable
12...30V DC
G 1/2" for reverse assembly
IP67
4
DARK-ON, LIGHT-ON
9701-0001
stainless steel